You can view the DFL case studies and FAQs here so that you can understand how to use the DFL data recovery tools better

This is one successful Western Digital HDD data recovery case study from one DFL user in India.

When the patient HDD was received, the HDD PCB was totally burnt, the ROM chip was corrupted and the original ROM content was not possible to read. Read more

How to recover lost data from Toshiba MQ01ABD032VS DVR locked HDD?
How to remove the DVR lock for Toshiba MQ01ABD032VS HDDs from Set-Top Boxes?

Patient HDD ID

TOSHIBA MQ01ABD032VS
Firmware version: AZ0U1Q
625142448 (298.09GB) Read more

This is one Hitachi patient HDD data recovery case study from one DFL user in Colombia.

HDD ID: Hitachi HDS721050CLA662
Capacity: 500GB

When this hdd was received, the drive was not detected and no data was available for data recovery. Read more

This is one Western Digital HDD data recovery case study from one DFL user in India.

When this patient HDD was connected to DFL-SRP WD hdd repair tool, the patient HDD could be slowly ready, but had error of 0A 0B read failure and all firmware modules read failure. Read more

Hi Stanley, the drive is failing to read after around 2% of the drive. All sectors red colour. Starting LBA of RW Request=00007DE280 Length=FFFFFFFF

ProcessRWError -Read- at LBA 00007DE280 Sense Code=44090082
Read more

“MCMT table is corrupted” is one very common firmware error output in the COM terminal. The following patient HDD is one firmware corrupted case from one Italian DFL user.

The following are the detailed error messages:

Tech Unlock Handshake: 0xC66A98E3 Read more

Please be kindly informed that Dolphin Data Lab Headquarter will be closed for Chinese National Day and Middle Autumn festival from October 1st to October 8th. Our office will re-open for business on Friday, October 9th 2020.

Here are some important notes about our work arrangement during this 8 day holiday. Read more

This Seagate patient HDD was recovered fully by Dolphin remote data recovery system and the user is one Indian DFL user. When the user connected the patient HDD to DFL-SRP Seagate HDD firmware repair tool,  powered on the HDD and got the “SP Regen FAIL, Update Mask” error and cannot enter F3 T>. Read more

This WD40EZRZ-00WN9B0 patient hard drive data recovery case study is done for one DFL user in Italy, the PCB number is 2060-771945-002.

After connecting the patient hard drive to DFL WD firmware repair hardware, the drive was not detected but the drive could be ready. Read more

As for Western Digital undetected or capacity 0 or wrong capacity hard drives, they are mostly firmware corrupted hard drives. The case study to be discussed today is from one DFL user in USA and the patient HDD model number is WD20EZRZ-00Z5HB0. Read more